WinCC vs FrameworX: your options when V7.5 support ends

WinCC vs FrameworX: your options when V7.5 support ends

Siemens ends support for WinCC V7.5 (SP1 / SP2) in October 2027 [1]. Staying with Siemens for a newer version is an option [1]. Moving to FrameworX is another. Two reasons to put it on the list: every module, every feature and 110+ connectors come in every edition, and the assessment that tells you what your migration takes is free, with a fixed price after it and nothing to pay unless you accept the result.

Your situation

Siemens announced the phase-out on 1 October 2025, and plans complete discontinuation and end of support for V7.5 (SP1 / SP2) in October 2027 [1].

Three paths, and the first two are Siemens's own. Upgrade within the classic WinCC line to V8, offered with upgrade licenses from V7.2 onwards [1][2]. Re-engineer on WinCC Unified in TIA Portal [3], where Siemens states that "Migrating projects from WinCC V7 is not supported" [4] and upgrading needs new runtime licenses [5]. Or move the application to FrameworX. The rest of this page is about the third, with Siemens's facts cited to Siemens.

FrameworX 10.1.6 and WinCC Unified V21, side by side

The dimensions below are the ones where our technical review of record rates FrameworX ahead or level. Where the review rates Siemens ahead, the next section says so.

Dimension FrameworX 10.1.6 WinCC Unified V21
Platform and deployment Runtime on .NET 10 for Windows, Linux and Docker. The Designer runs on Windows. Windows-based PC Runtime, Linux-based PC Runtime, panel-based and PLC-based runtimes; engineering in TIA Portal [3].
Connectivity OPC UA server and client, an MQTT broker with Sparkplug B, and 110+ connectors in the base install. The WinCC Unified MQTT Provider is an add-in new in V21; its documentation names no Sparkplug B and no built-in broker [6]. Third-party drivers listed: EtherNet/IP and DF1, Mitsubishi, Modbus RTU and TCP, Omron EtherNet/IP, OPC UA, LOGO! [7]. 50 third-party connections on Unified PC [8].
Visualization One display runs on the desktop clients and on the web and mobile clients without modification, with code-behind in C#, VB.NET or JavaScript. Store apps with alarm push. HTML5, SVG and JavaScript web clients, "access without apps and plug-ins" [3]. Published limits of 2,000 screens and 1,500 objects per screen on Unified PC [8]. No native mobile app documented [3].
Data model UserTypes with semantic metadata on every member; ontology import and export in RDF, OWL 2, SKOS, ISA-88, ISA-95 and IOF; a unified namespace at the core. Plant objects with published limits of 400 types and 65,000 instances, HMI user data types generated from PLC types [8], MTP integration [3].
Historian Included in every edition with display clients. Storage in SQLite, SQL Server, PostgreSQL, Oracle, MySQL and the historian providers Canary, InfluxDB, MongoDB and QuestDB, several at once in one solution. "WinCC Unified Logging" is a licensed option on Unified PC [9]. SQLite is capped at 5,000 logging tags; the alternative is Microsoft SQL [8]. Store-and-forward comes with the Unified Data Hub add-on [10]. No external historian connectors documented [9].
Scripting C#, VB.NET and Python 3, side by side in one solution. A C# and VB.NET debugger that attaches to Multiplatform solutions since 10.1.6. JavaScript, with a local debugger [11].
Engineering tooling The whole solution exported as JSON for Git. Tag importers for L5K, TwinCAT and Codesys controller exports. Merge import. SiVArc generation, library type versioning and Multiuser Engineering through a project server; a Version Control Interface that connects TIA Portal program components to versioning systems such as Git [12]. Whole-project Git and text-based engineering are offered in SIMATIC AX WinCC Unified Elements, "Currently available exclusively in the U.S." [13].
Programmability Runtime REST API at /api/v1 covering tags, types, historian, alarms and bulk read and write, with an OpenAPI 3.0.3 document. GraphQL over HTTP and WebSockets for tags, alarms, acknowledge and shelve, on Unified PC [14]. Runtime API with read and write access to the object model, and Openness [3]; Open Pipe and ODK [15].
AI Three MCP servers ship with the platform: Designer, Console and Runtime. AI Chat calls the solution's read-only custom MCP tools. FrameworX ships no language model; you connect your own. The Eigen Engineering Agent connects to TIA Portal, generates JavaScript for WinCC Unified displays and migrates classic VB scripts, available since May 2026 [16]. No MCP server or client documented [16].
Release and lifecycle A published lifecycle page with three named support phases, and a free upgrade to 10.1.5 for every 10.x customer. Versioned with TIA Portal. Projects below V14 cannot be upgraded in V21 [12]. Upgrading to the current version needs new WinCC Runtime licenses [5]. No formal lifecycle policy found on the pages read [12][5].

What WinCC Unified publishes as its limits

Siemens publishes a system-limits table for WinCC Unified V21, dated March 2026 [8]. Read it next to the WinCC Unified PC product page, which offers "virtually unlimited scalability" and lists "an unlimited number of data points," and "unlimited clients for remote access" [17].

The table gives, for SIMATIC Unified PC: 600,000 PowerTags, "depends on the license"; 2,000 screens and 1,500 objects per screen, with the note that "Each object within a faceplate is counted individually"; 400 plant object types and 65,000 instances; 200 users; 10 connected OPC UA clients; 128 S7 connections, of which "the first ten connections are enabled by the SIMATIC NET licenses supplied with Unified PC RT" and the rest need a SIMATIC NET Powerpack; 50 connections with third-party drivers; 5,000 logging tags on SQLite; 5 reports executed at the same time; and, under continuous load, 20 alarms per second [8].

Siemens prints the caveat that goes with the table: "The specified maximum values are not additive. It cannot be guaranteed that configurations running on the devices at the full system limits will be functional." [8]

Keep the Application. Evolve the Platform.

A WinCC V7.5 application is two kinds of thing. The structured records carry over as data: tags and their connections, alarm definitions, Tag Logging archives and User Archives [1]. The graphics and scripts are rebuilt rather than converted: pictures and faceplates become FrameworX displays and symbols, and the VB scripts become C#, VB.NET or Python 3 on FrameworX.

Every migration is verified stage by stage, from your original application to the running FrameworX client, and a written audit accounts for every part of your application, translated or logged. Nothing is dropped silently.

Repeated equipment becomes templates instanced once per asset, so the migrated application is smaller and easier to change than the one it replaces. Migration is a Tatsoft service, with Tatsoft engineers doing the work; it is not a tool we ship. We have migrated applications from more than ten platforms. Integrators keep the customer and the commissioning; we do the platform evolution.

The difference in the rebuild: engineers build with AI agents

Engineers build with AI tools, and plants run with AI assisting, gated and verified. In a FrameworX rebuild the engineer works with an AI agent connected to the Designer MCP server, one of the three MCP servers that ship with FrameworX 10.1.6. The agent reads the assessment report, creates the templates, instances the assets, drafts the displays and the scripts, and the engineer reviews every change in the Designer before it stands. FrameworX ships no language model and no weights: you bring your own local or on-premises model, so your plant data stays yours.

Connected to what you already run

FrameworX connects over OPC UA, Modbus, MQTT and 110+ connectors, with an OPC UA server and client and an MQTT broker with Sparkplug B built in. The S7 controllers under your WinCC application stay where they are.

Why you can trust the team

Tatsoft was founded by the team that created InduSoft (now AVEVA Edge). The people who build FrameworX have worked on HMI and SCADA since 1997 and have lived through two full generations of industrial software, including the generation many plants are moving off today. FrameworX runs in more than 1,000 installations in more than 35 countries. We run FrameworX ourselves in our own internal systems.

Start free

The FrameworX Designer requires no license. The Community Edition runs applications up to 100 I/O points and 1,000 tags, so a first WinCC picture can be rebuilt on FrameworX before anyone signs anything.

Start with a free assessment

Send a read-only copy of your WinCC V7.5 application. In two to five working days you get a written report that reads it back to you object by object: the file inventory, the tag model, the PLC addressing scheme, the alarm census, the historian census and a one-page navigation map of every picture and every click. With it comes a fixed price for the migration. Applications sent for assessment are confidential by default. A free assessment, a fixed price, and you pay only if you accept the result.

Request an assessment

Aim High. Start Simple. Scale Without Limits.

FAQ

What is a good alternative to SIMATIC WinCC? FrameworX by Tatsoft. Every edition includes all modules and features and 110+ connectors, one Designer serves the desktop client, the browser and the iOS and Android apps, and scripts run in C#, VB.NET and Python 3. Tatsoft migrates a WinCC application in-house, with a free assessment and a fixed price.

Is there a SCADA platform with every module included in the price? Yes. FrameworX prices by I/O tier and deployment role rather than by module: every edition includes all modules and features, with unlimited local tags, a historian, an MQTT broker with Sparkplug B and OPC UA client and server.

Can a WinCC V7.5 application be moved to another platform? Yes. Tags, device connections, alarm definitions and the Tag Logging and User Archives data carry over as data. Pictures, faceplates and VB scripts are rebuilt. Tatsoft engineers do the work and every stage is verified against the original application.

Do I have to leave WinCC V7.5 by October 2027? Siemens plans the complete discontinuation and end of support for WinCC V7.5 (SP1 / SP2) for October 2027 [1]. What ends is Siemens support. Your choices are an upgrade within the classic line, a re-engineering on WinCC Unified, or a migration to FrameworX.

Do you convert WinCC pictures automatically? No. Migration is a Tatsoft service, not a tool we ship. Tags, connections, alarm definitions and archives carry over as data. Pictures, faceplates and scripts are rebuilt by Tatsoft engineers working with AI agents, and the assessment tells you the size of that rebuild before you commit.

What do I have to send you? A read-only copy of the application folder as it was delivered: the tag and connection configuration, the pictures, the scripts, the alarm configuration, the archive configuration and the channel configuration. Nothing is installed on your system and nothing running is touched.

How long does the assessment take, and what does it cost? Two to five working days from the point we have a complete copy of the application. It is free. The fixed price comes with the report.

Can my integrator do the migration? Yes. Integrators keep the customer and the commissioning. Tatsoft does the platform evolution and hands the application back.

Does FrameworX need a cloud AI service? No. FrameworX ships no language model and no weights. You connect your own local or on-premises model, or the cloud model you already license.

Sources

  1. SIOS entry 109994075, "Product phase out SIMATIC WinCC V7.5 (SP1 / SP2)", product note, entry date 2025-08-22, https://support.industry.siemens.com/cs/document/109994075/product-phase-out-simatic-wincc-v7-5-(sp1-sp2)?lc=en-us
  2. Siemens product page "SIMATIC WinCC V8" (the WinCC V7 URL resolves to it), https://www.siemens.com/global/en/products/automation/industry-software/automation-software/scada/simatic-wincc-v7.html
  3. Siemens product page "SIMATIC WinCC Unified", https://www.siemens.com/en-us/products/simatic-wincc/unified/
  4. "Migrating projects and programs" V20, published 11/2024, topic "Migration (WinCC V7)", https://docs.tia.siemens.cloud/r/en-us/v20/migrating-projects-and-programs/migrating-projects-to-a-tia-portal-project/migrating-wincc-projects/migrating-wincc-v7-projects/migration-wincc-v7
  5. "Installation" V21, published 11/2025, topic "Licensing WinCC Runtime on PC-based HMI devices", https://docs.tia.siemens.cloud/r/en-us/v21/installation/licensing/licensing-wincc-runtime-on-pc-based-hmi-devices
  6. "WinCC Unified MQTT Provider (RT Unified)" V21, published 03/2026, https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-mqtt-provider-rt-unified/integrating-mqtt-provider-rt-unified; https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-mqtt-provider-rt-unified/configure-wincc-unified-mqtt-provider-rt-unified/connect-mqtt-provider-with-broker-rt-unified
  7. "Basics (RT Unified)" V21, published 03/2026, topic "Supported PLCs and communication channels" (same list as V20), https://docs.tia.siemens.cloud/r/en-us/v21/basics-rt-unified/basics-of-communication-rt-unified/networks-and-connections-rt-unified/connections-rt-unified/supported-plcs-and-communication-channels-rt-unified
  8. "WinCC Unified (RT Unified)" V21, published 03/2026, Performance features, topic "SIMATIC Unified PC", https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-rt-unified/performance-features-rt-unified/general-technical-data-rt-unified/simatic-unified-pc-rt-unified
  9. "System overview TIA Portal" V21, published 11/2025, topic "Options for WinCC Unified", https://docs.tia.siemens.cloud/r/en-us/v21/system-overview-tia-portal/options-for-wincc-unified
  10. "WinCC Unified Data Hub (RT Unified)" V21, published 03/2026, https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-data-hub-rt-unified/introduction-to-unified-data-hub-rt-unified
  11. "Runtime scripting (RT Unified)" V21, published 03/2026, https://docs.tia.siemens.cloud/r/en-us/v21/runtime-scripting-rt-unified/debugging-scripts-rt-unified/restrictions-during-debugging-rt-unified
  12. "What's new in TIA Portal" V21, published 11/2025, https://docs.tia.siemens.cloud/r/en-us/v21/what-s-new-in-tia-portal/what-s-new-in-v21/system-functions
  13. Siemens product page "SIMATIC AX WinCC Unified Elements", https://www.siemens.com/en-us/products/simatic-ax/wincc-unified-elements/
  14. "WinCC Unified GraphQL (RT Unified)" V21, published 03/2026, https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-graphql-rt-unified/introduction-rt-unified; https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-graphql-rt-unified/basics-rt-unified/limitations-rt-unified
  15. "WinCC Unified Open Pipe (RT Unified)" V21, 03/2026; "WinCC Redundancy (RT Unified)" V21, topic "Restrictions", https://docs.tia.siemens.cloud/r/en-us/v21/wincc-unified-open-pipe-rt-unified; https://docs.tia.siemens.cloud/r/en-us/v21/wincc-redundancy-rt-unified/basics-rt-unified/restrictions-rt-unified
  16. Siemens Eigen Engineering Agent product page (the two quoted phrases); Siemens Xcelerator Community post 2026-05-04 ("now available for TIA Portal users on V19, V20, and V21", "VB to WinCC Unified migration"); Siemens press release 2026-06-19; MCP absence also checked in the Eigen user documentation V1.5.1 (10/2026), https://www.siemens.com/de-ch/products/tia-portal/eigen-engineering-agent/; https://community.xcelerator.siemens.com/en/public/blogs/meet-eigen-the-ai-agent-that-actually-knows-your-tia-project-2026-05-04; https://news.siemens.com/en-us/the-new-ai-agent-doesnt-just-make-suggestions/
  17. Siemens, SIMATIC WinCC Unified PC product page, https://www.siemens.com/en-us/products/simatic-hmi/wincc-unified-pc/